-
MULT +5024W -24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh280,000.00 -
MULT +3048W -48V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh195,000.00 -
MULT +3024W -24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh190,000.00 -
MULT 11+3000W -24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh180,000.00 -
MULT +3000W -24V INV.CHARGER – VICTRON easy solar
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh280,000.00 -
MULT +2000W -12/24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh150,000.00 -
MULT +1600W – 12/24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh125,000.00 -
MULT +1224W -24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh115,000.00 -
MULT +1212W -12V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh98,000.00 -
MULT +824W -24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh85,000.00 -
MULT +812W -12V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh85,000.00 -
MULT +500W -24V INV.CHARGER – VICTRON
1)Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
– output short circuit
– overload
– battery voltage too high
– battery voltage too low
– temperature too high
– 230 VAC on inverter output
– input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source availableKSh50,000.00