Solarvet Hybrid Pump Inverter with MPPT Functions

Solarvet Hybrid Pump Inverter with MPPT Functions

Solarvet Hybrid Pump Inverter with MPPT Functions in a Solar Pumping system becomes more and more popular, it can be applied to daily ( underground water), agriculture  irrigation, forestry irrigation, desert control, pasture animal husbandry, water supply for islands, wastewater treatment  engineering , and so on.
In recent years, with the promotion of the utilization of new energy resources, solar pumping systems are more and more used in municipal engineering, city centre squares, parks, tourist sites, resorts and hotels, the landscapes and fountain systems in the residential areas. This system is composed of a solar array, a pump and solar pumping inverter, or GPRS remote control model.
Based on the design philosophy that it is better to store water than electricity, there is no energy storing device such as store battery in the system.

Technical specification of solarvet Hybrid pump inverter
**Solarvet Hybrid pump drive specification when FA-00 set to 1&2 for solar pumping controlling function.
Recommended MPPT voltage range Vmpp 131 to 350 VDC for 1S (80V to 350VDC input, 3PH 110 to 220VAC output)
Vmpp 280 to 375VDC for 2S ( 150V to 450VDC input, 3PH 220 to 240VAC output)
Vmpp 486 to 750 VDC for 4T ( 350V to 800VDC input, 3PH 380 to 460VAC output)
Recommended input Voc and Vmpp voltage Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps
Voc 355(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps
Voc 621(VDC), Vmpp 540(VDC) for 4T model or 380V AC pumps
Motor type Control for permanent magnet synchronous motor and asynchronous motor pumps.
Rated output voltage 3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V
Output frequency range 0~maximum frequency 600Hz.
MPPT efficiency 97%,
Ambient temperature range G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s
P type for general pumps, 120% rated current for 60s, 150% rated current for 2s
Solar pump control special performance MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected
Protection function Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection
Protection degree IP20, Air force cooling
Running mode MPPT or CVT
Altitude Below 1000m; above 1000mderated 1% for every additional 100m.
Standard
AC input  backup circuit
CE, Design based on vector control drive S300 and S3200 series, more specification please refer to S300 or S320 vector control drive operation manual
Technical specification when it used for speed and torque controlling of motor as FA00 set to 0.
voltage, frequency Single phase 220V, 3 phase, 220V,380V660V and 1140V.
Power 0.75kw to 37kw.
Control mode 0: VF control ; 1: Vectorized VF control ; 2:Open loop vector control 1 ; 3: High performance open loop vector control 2
Maximum frequency 0-650Hz
Multi-functions PID Control, Carrier Frequency Adjustable, Current Limiter, Speed Search, Momentary Power Loss Restart,16 Step Speed (Max), 3-Wire connection, Slip Compensation, Frequency Jump,  DC braking, Upper/Lower Frequency, Torque control, Compatible for PMSM and IM, built in RS485, counting, fault information checking, fully fault protection function, frequency combination reference.

You cannot copy content of this page

error: Content is protected !!

Main Menu